Datasheet

771 mA Process Clamp Meter
11191-eng Rev. 01
Fluke 771
Included Accessories
Soft carrying case, users manual
Ordering Information
Fluke 771 Milliamp Process Clamp Meter
The Fluke 771 is the latest innovative
approach to measuring mA loop signals.
With the Fluke 771 you no longer need to
lift a wire from a terminal (break the loop)
to measure 4-20 mA which has a direct
impact on your maintenance time. With the
Fluke 771 there is no need to call a control
room to override the control of a process
loop when breaking the loop and you save
time when testing analog I/O on a PLC if
you do not need to check measurements on
a console. In addition, the Fluke 771 can
have another impact on your overall cost
by eliminating catastrophic plant outage
caused by accidentally opening a critical
loop.
Measure 4-20 mA signals without
breaking the loop
Measure mA signals for PLC and control
system analog I/O
Measure 4-20 mA output signals from
transmitters without breaking the loop
Best in class 0.2% accuracy
Resolution and sensitivity to 0.01 mA
Hold function captures and displays
changing measurements
Dual backlit display with both mA
measurement and percent of 4-20 mA
span
Measurement Spotlight illuminates hard
to see wires in dark enclosures
Detachable clamp with extension cable
for measurements in tight locations
Measure 10-50 mA signals in older
control systems using the 99.9 mA range
Automatic battery savings features
- Power, 15 minutes automatic power
down
- Backlight, 2 minutes, automatic off
- Spotlight, 2 minutes, automatic off
Automatic battery saving features can be disabled if desired.
Function Range Resolution Accuracy Features
Measuring and troubleshooting -20.99 to 0.01 mA 0.2% or reading + Zero, Hold,
4-20 mA signals +20.99 mA 5 counts backlight,
measurement
spotlight
Measuring and troubleshooting -21.0 to -99.9 mA 0.1 mA 1% reading + Zero, Hold,
10-50 mA signals +21.0 to +99.9 mA 5 counts backlight,
measurement
spotlight
Specifications
Operating Temperature: -10 to 55 ºC
Storage Temperature: -25 to 70 ºC
Operating Humidity: < 95% @ <30 ºC,
< 75% @ 30 to 55 ºC
Operating Altitude: 0 to 2000 m
IP Rating: IP 40
Size (HxWxD): 212 mm x 59 mm x 38 mm
Weight: 0.26 kg
Vibration: Random 2g, 5 to 500 Hz
Shock: 1 meter drop test (except the jaw)
Safety: EMI, RFI, EMC - Meets EN61326-1
Temperature Coefficients: 0.01% / ºC
Battery: AA 1.5 V Alkaline (2), IEC LR6
Battery Life: 20 hours typical
Warranty: Three-years, electronics,
1-year for clamp cable assembly