Vibration meter
Low frequency range
(overall measurement)
10 Hz to 1,000 Hz
High frequency range
(CF+ measurement)
4,000 Hz to 20,000 Hz
Severity levels Good, Satisfactory, Unsatisfactory,
Unacceptable
Vibration limit 50 g peak (100 g peak-peak)
A/D converter 16-bit
Signal to noise ratio 80 dB
Sampling rate
Low frequency 20,000 Hz
High frequency 80,000 Hz
Real time clock backup Coin battery
Sensor
Sensitivity 100 mV / g ± 10%
Measurement range 0.01 g to 50 g
Low frequency range
(overall measurement)
10 Hz to 1,000 Hz
High frequency range
(CF+ measurement)
4,000 Hz to 20,000 Hz
Resolution 0.01 g
Accuracy At 100 Hz ± 5 % of measured value
Amplitude units
Acceleration g, m/sec
2
Velocity in/sec, mm/sec
Displacement mils, mm
Infrared thermometer (temperature measurement)
Range -20 °C to 200 °C (-4 °F to 392 °F)
Accuracy ±2 °C (4 °F)
Focal length Fixed, at ~3.8 cm (1.5 )
External sensor
Note: Fluke supports, but does not provide, external sensors.
Frequency range 10 Hz to 1,000 Hz
Bias voltage (to supply power) 20 V dc to 22 V dc
Bias Current (to supply power) Maximum 5 mA
Firmware
Calibration Factory calibration required
External interfaces USB 2.0 (full speed) communication
Data capacity Database on internal flash memory
Upgrade through USB
Memory Up to 3,500 measurements
Radiated emission
Electrostatic discharge: Burst Standard EN 61000-4-2
Electromagnetic interference Standard EN 61000-4-3
RE Standard CISPR 11, Class A
Ordering information
Fluke-805 Vibration Meter
Includes: 805 Vibration Meter, USB cable,
storage case, belt holster, quick reference
guide, CD-ROM (includes MS Excel template
and documentation), and two AA batteries
Environmental
Operating
temperature
-20 °C to 50 °C (-4 °F to 122 °F)
Storage
temperature
-30 °C to 80 °C (-22 °F to 176 °F)
Operating
humidity
10 % to 95 % RH
(non-condensing)
Operating/
Storage altitude
Sea Level to 3,048 meters
(10,000 feet)
IP rating IP54
Vibration limit 500 g peak
Drop test 1 meter
General specifications
Battery type AA (2) Alkaline or Lithium-ion 2
V dc
Battery life 250 measurements
Size (L x W x H) 25.72 cm x 16.19 cm x 9.84 cm
(10.13 in x 6.38 in x 3.875 in)
Weight 1.16 kg (2.55 lb)
Connectors USB mini-B 7-pin, stereo audio
output jack (3.5 mm Audio
Plug), external sensor jack (SMB
connector)