Datasheet

80 Series V
Digital Multimeters
Performance and accuracy for
maximum industrial productivity
The new Fluke 80 Series V has improved
measurement functions, troubleshooting
features, resolution and accuracy to solve
more problems on motor drives, in plant
automation, power distribution, and
electro-mechanical equipment. The
80 Series V operates very similar to the
classic 80 Series, but with more problem-
solving power, safety, convenience and
impact protection.
The new Fluke 87V has a unique function
for accurate voltage and frequency
measurements on adjustable speed
motor drives and other electrically noisy
equipment.
A built-in thermometer conveniently
allows you to take temperature readings
without having to carry a separate
instrument.
Electrical safety
All inputs are protected to EN61010-1
(2
nd
edition) CAT III, 1000 V and CAT IV
600V. They can withstand impulses in
excess of 8.000 V and reduce risks
related to surges and spikes.
Accessories and
Ordering Information
Included Accessories
TL75 test leads, AC72 alligator clips, holster,
80BK temperature probe (87V only), 9 V
battery (installed), CD-ROM (user’s manual
and technical notes) and operator’s guide.
Ordering Information
Fluke 83V Multimeter
Fluke 87V True RMS Multimeter
Fluke 87V/E Industrial Electrician Combo Kit
83V 87V*
Max. resolution Accuracy Max. resolution Accuracy
0.1 mV ±(0.1+1%) 10 µV ±(0.05%+1)
0.1 mV ±(0.5%+2) 10 µV ±(0.7%+2)
0.1 µA ±(0.4%+2) 0.01 µA ±(0.2%+2)
0.1 µA ±(1.2%+2) 0.01 µA ±(1.0%+2)
0.1 ±(0.4%+1) 0.01 ±(0.2%+1)
0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)
0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)
0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)
-0.1 ºC1.0%
--2.2 ºC or 2%
Functions Maximum Range
Voltage DC 1000 V
Voltage AC 1000 V
Current DC 10 A **
Current AC 10 A **
Resistance 50 M
Conductance 60 nS
Capacitance 9999 µF
Frequency > 200 kHz
Temperature -200 to 1090 ºC
80BK temperature probe - 40 to 260 ºC
Accuracies are best accuracies for each function.
* 87V accuracy is stated for 6.000 counts and resolution for 20.000 counts
** 20 A up to 30 seconds
Battery Life : Over 400 hours typical (alkaline).
Size (without holster) (HxWxD): 186 mm x 86 mm x 32 mm
Weight : 0.36 kg
Lifetime Warranty
FeaturesSpecifications
(Check the Fluke Web for detailed specifications)
Features
True-RMS voltage and current for accurate measurements on
non linear signals
Bandwidth (voltage/current)
Digital display counts (default/selectable)
Selectable filter for accurate voltage and frequency
measurements on motor drives
Large display with analog bargraph and 2 level bright white
backlight
Auto and manual ranging for maximum flexibility
Built-in thermometer lets you carry one less tool
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead resistance from low ohms
measurements
Min-Max-Average recording with Min/Max Alert to capture
variations automatically
Touch Hold
®
to capture stable readings avoiding noisy signals
Audible continuity, diode test and duty cycle
Input Alert
“Classic” design with new removable holster with built in
test lead and probe storage
Improved selectable sleep mode for long battery life
Easy battery and fuse exchange without opening the
complete case
83V 87V
5 kHz 20 kHz
6000 20000 / 6000
●●
●●
●●
●●
●●
●●
●●
●●
●●
●●
●●
True RMS
New

Summary of content (2 pages)