Measure Capacitance
1. Turn off power to the circuit.
2. Disconnect and discharge the capacitor.
3. Turn the rotary switch to
.
4. Take the measurement noting the correct polarity of the
capacitor.
If the capacitor requires more discharging, diSC shows while the
capacitor discharges.
Measure AC Current
XW Warning
To prevent possible electrical shock, fire, or
personal injury:
Remove Test Leads before making current
measurements.
Do not hold the Product anywhere beyond the
tactile barrier (see Figure 4).
1. Turn the rotary switch to
.
2. Center the wire within the clamp jaws below the horizontal line
located on the clamp (see Figure 4).
Note
Measure one wire at a time because currents moving in
different directions will cancel each other out (see
Figure 4).