Backlight
Push to toggle the backlight on and off. The backlight
automatically turns off after 2 minutes.
To disable the automatic backlight timeout:
1. Hold and turn on the Product.
2. Push .
MIN MAX Recording Mode
The MIN MAX recording mode captures the minimum and
maximum input values. When a new high or low is detected, the
Product beeps.
To use this feature:
1. Turn the rotary switch to the desired measurement function.
2. Push to enter MIN MAX Mode.
and the highest reading detected since entering MIN
MAX mode show on the display.
3. Push to step through the minimum (MIN) and present
readings.
4. To pause MIN MAX recording without erasing stored values,
push . shows on the display.
5. To resume MIN MAX recording, push again.
6. To exit MIN MAX mode and erase stored readings, push
for at least 2 seconds.