Specifications

Common Questions LR-AT Can Solve
9
Q > Does this RJ45 drop support PoE?
A > Use Tools to specify the desired PoE power class and
use Switch or AutoTest to verify the power under load
up to 25.5W (802.3at).
Q > What speed/duplex is this device configured for?
A > Use Switch to check the advertised and actual speed/
duplex. Additionally, use Tools to tests for manual (non-
Auto Negotiated) speed/duplex.
Q > Can I see traffic from this connection?
A > Observe the utilization LED blinking to see network
traffic.
Q> Can I connect in a MAC access control environment?
A> Use Tools > VLAN/MAC to specify a user defined MAC
address.
Q > Do I have network connectivity?
A > Select AutoTest to validate key network services
(DHCP, DNS, Router).
Q > Can I get an IPv4 DHCP address?
A > Select AutoTest. Select DHCP (or enter a static IP
address) in the Tools > IP Configuration menu.
Q> Can I get an IPv6 address?
A > Enable IPv6 in Tools > IP Configuration. Use AutoTest
to observer the acquired IPv6 link-local and global
address.
Q > Can I PING?
A > Select AutoTest. Configure an address to Ping under
Tools > AutoTest Configuration.
Q> Can I verify application connectivity?
A > Select AutoTest. Configure an address and
application port (e.g. port 80 for web/HTTP) under Tools
> AutoTest Configuration.
Q > Can I use it for throughput testing?
A> Use the Reflector tool (setup under Tools - only
available on LR-AT 2000 model).
Q > Can I connect to an 802.1X port?
A > Use the Tools > Connect Configuration screen to
enable 802.1X. Also, use the LinkRunner Manager PC