Data Sheet

3 Fluke Corporation TiX560 and TiX520 Infrared Cameras: The Fluke Expert Series
TiX560 TiX520
Data storage and image capture
Extensive memory options Removable micro SD memory card, on-board flash memory, save-to-USB flash drive capability, direct download via USB-to-PC connection
Image capture, review, save mechanism One-handed image capture, review, and save capability
Post-capture image editing (on camera) Yes. Conduct on camera analysis for in-field results
Advanced text Annotation Yes. Including standard shortcuts as well as user programmable options
File formats Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory review Thumbnail view navigation and review selection
Software SmartView
® software, Fluke Connect
(where available), and SmartView® Mobile App—full analysis and reporting software
Export file formats with SmartView
® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided*
IR-PhotoNotes
Yes
Text annotation Yes
Video recording Standard and radiometric
File formats video Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Remote control operation Yes
Auto capture (temperature and interval) Yes
Battery
Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life Three hours continuous use per battery pack
Battery charge time 2.5 hours to full charge
Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving User selectable sleep and power off modes
Temperature measurement
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +1200 °C (-4 °F to +2192 °F) -20 °C to +850 °C (-4 °F to +1562 °F)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature
compensation
Yes
On-screen transmission correction Yes
Color palettes
Standard palettes 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast
palettes (8) Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
General specifications
Color alarms (temperature alarms) High-temperature and low-temperature
Infrared spectral band 7.5 m to 14 m (long wave)
Temperature Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Center-point temperature measurement Yes
Spot temperature Hot and cold spot markers
User-definable spot markers 3 user-definable spot markers
Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
Safety IEC 61010-1: Overvoltage Category II, Pollution degree 2
Electromagnetic compatibility IEC 61326-1: Basic EM Environment; CISPR11, Group 1, Class A
Australian RCM IE 61326-1
US FCC CFR 47, Part 15 Subpart B
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock/Drop 25 g, IEC 68-2-29/Engineered to withstand 1 meter (3.3 feet) drop with standard lens
Size (H x W x L)/Weight (battery included) 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)/1.54 kg (3.4 lb)
Enclosure rating IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty/Calibration cycle Two-years (standard), extended warranties are available/Two-years (assumes normal operation and normal aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese,
Spanish, Swedish, Traditional Chinese, and Turkish