Specifications

6223C-PUD
FN-LINK TECHNOLOGY LIMITED Proprietary & Confidential Information
9
0: WLAN off, PCIe off
29 PCIe_WAKE O/D
Power management event: open drain,active low.
Used to reactivate the PCIe slot’s main power rails
and reference clocks.
Share with BT wake up host function via sideband signals.
VDDIO
30 CLKREQ I/O/D
PCI-e reference clock request signal.
Can be shared with BTdevice clock request function
VDDIO
31 PERST I PCI-e reset signal:active low. VDDIO
32 GND grounding
33 REFCLKN0 I PCI-E CLK Difference -
34 REFCLKP0 I PCI-E CLK Difference +
35 GND grounding
36 HSON O PCI-E Data Out Difference -
37 HSOP O PCI-E Data Out Difference +
38 GND grounding
39 HSIN I PCI-E Data IN Difference -
40 HSIP I PCI-E Data IN Difference +
41 GND grounding
42 NC No connect
43 NC No connect
44 NC No connect
45 NC No connect
46 NC No connect
47 NC No connect
48 NC No connect
49 NC No connect
50 NC No connect
51 NC No connect
52 NC No connect
53 NC No connect
54 NC No connect
55 NC No connect
56 NC No connect
57 GND grounding
58 PCM_SYNC I/O PCM sync signal VDDIO
59 PCM_IN I PCM data input VDDIO