Product Specs

6223H-SRD
FN-LINK TECHNOLOGY LIMITED
21
13. Moisture sensitivity
The Modules is a Moisture Sensitive Device level 3, in according with standard IPC/JEDEC
J-STD-020, take care
all the relatives requirements for using this kind of components.
Moreover, the customer has to take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity (RH)
b) Environmental condition during the production: 30°C / 60% RH according to IPC/JEDEC J-STD-033A
paragraph 5
c) The maximum time between the opening of the sealed bag and the reflow process must be 168 hours if
condition
d) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected
e) Baking is required if conditions b) or c) are not respected
f) Baking is required if the humidity indicator inside the bag indicates 10% RH or more