Product Brochure
EXTERIOR FINISH R-VALUE
INSULATING
BLANKET
THICKNESS (IN.)
DESIGN THERMAL RESISTANCE (R) VALUE
(WINTER CONDITIONS) FOR FOAMULAR
®
THICKNESS
(1)
1/2"
(R-3)
3/4"
(R-4)
1"
(R-5)
3/4" Wood Siding 1.05
3 1/2" R13
3 1/2" R15
6 1/4" R19
18.50
20.50
24.50
19.45
21.45
25.45
20.76
22.76
26.76
1/2" Plywood Hardboard Siding .62
3 1/2" R13
3 1/2" R15
6 1/4" R19
18.07
20.07
24.07
19.02
21.02
25.02
20.33
22.33
26.33
Vinyl Siding .71
3 1/2" R13
3 1/2" R15
6 1/4" R19
18.16
20.16
24.16
19.11
21.11
25.11
20.42
22.42
26.42
4" Face Brick .44
3 1/2" R13
3 1/2" R15
6 1/4" R19
18.90
20.90
24.90
19.85
21.85
25.85
21.16
23.16
27.16
1" Stucco .20
3 1/2" R13
3 1/2" R15
6 1/4" R19
17.65
29.65
23.65
18.60
20.60
24.60
19.91
21.91
25.91
†
The higher the R-value, the greater the insulation value. Find out why in the Seller’s Fact Sheet on R-values.
* Nominal thickness
FOAMULAR
®
PINK Foam Insulation is produced using the Owens Corning
™
patented HYDROVAC
®
process technology.
Note: (1) resistances are calculated, including Inside/Outside air lms, based upon procedures and design values
for all components at 75° F mean temperature from current ASHRE Handbook of Fundamentals.
TheRMAL ReSISTANCe R-VALUeS
†
FOR TYPICAL FRAMeD WALL
PROPERTY TEST METHOD
2
FOAMULAR
®
150
Insulation
INSULPINK
®
Insulating Sheathing
PROPINK
®
IS
Half-Inch Insulation
FOAMULAR
®
250
Insulation
INSUL-DRAIN
®
Insulation
PINK-DRAIN
®
Insulation
FOAMULAR
®
400
Insulation
Thermal Resistance, R-Value (180 day)
3
,
minimum, ºF * ft
2
* hr/btu (RSI, ºC * m
2
/W)
ASTM C518 R-5/inch R-5/inch R-5/inch
Compressive Strength, minimum psi (kPa)
4
ASTM D1621 15
25 (172)
PINK-DRAIN
®
: 30(207)
40 (276)
Flexural Strength, minimum psi (kPa)
5
ASTM C203 60 (414) 75 (517) 115 (793)
Water Absorption, maximum % by volume
6
ASTM C272 0.1 0.1 0.05
Water Vapor Permeance, maximum perm (ng/Pa/s/m
2
)
7
ASTM E96 1.5 (86) 1.5 (86) 1.1 (63)
Dimensional Stability, maximum % linear change
ASTM D2126 2.0 2.0 2.0
Flame Spread
8, 9
ASTM E84 5 5 5
Smoke Developed
8, 9, 10
ASTM E84 45-175 45-175 45-175
Oxygen Index, minimum % by volume
8
ASTM D2863 24 24 24
Service Temperature, maximum °F (°C) - 165 (74) 165 (74) 165 (74)
Linear Coefcient of Thermal Expansion, in/in/ ºF (m/m/°C) ASTM E228 3.5 x 10
-5
(6.3x10
-5
) 3.5 x 10
-5
(6.3x10
-5
) 3.5 x 10
-5
(6.3x10
-5
)
Type Classications ASTM C578 Type X Type lV Type Vl
1. Properties shown are representative values for 1" thick material, unless otherwise specied. Testing modied as
needed for products less than 1/2" thickness.
2. Modied as required to meet ASTM C578
3. R means the resistance to heat ow; the higher the value, the greater the insulation power. This insulation
must be installed properly to get the marked R-value. Follow the manufacturer’s instructions carefully. If
a manufacturer’s fact sheet is not provided with the material shipment, request this and review it carefully.
R-values vary depending on many factors including the mean temperature at which the test is conducted,
and the age of the sample at the time of testing. The R-value for FOAMULAR
®
XPS is provided from testing
at two mean temperatures, 40º F and 75 º F, and 180 day real-time aged (as mandated by ASTM C578). The
R-value at 180 day real-time age and 75º F mean temperature is commonly used to compare products and is
the value printed on the product.
4. Values at yield or 10% deection, whichever occurs rst. Testing modied as needed for products less than
1/2" thickness.
5. Value at yield or 5%, whichever occurs rst
6. Data ranges from 0.00 to value shown due to the level of precision of the test method
7. Water vapor permeance decreases as thickness increases
8. These laboratory tests are not intended to describe the hazards presented by this material under actual
re conditions
9. Data from Underwriters Laboratories Inc.
®
classied. See Classication Certicate U-197
10. ASTM E84 is thickness-dependent, therefore a range of values is given
FOAMULAR
®
INSULATION PhYSICAL PROPeRTIeS
(1)