Quick Start Manual
110 Series Ice and Water Dispensers 5
Speci cations
Electrical
1. Models with RIDE ice machines (110CR400A/W)
Ice machine Max. fuse Dispenser Max. fuse
Basic electrical: 115V/60Hz/1 phase 11.0A 20A 4.0A 20A
2. Freestanding models and models with integral ice machines (110FB400A/W, 110CT400A/W)
Total system Max. fuse
Basic electrical: 115V/60Hz/1 phase 14.0A 20A
3. Dispensers and RIDE ice machines are supplied with 7-foot power cord with NEMA 5-20 hospital grade plug.
Connect to 20A circuit fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Ambient
Air temp 100 F/38 C max. 50 F/10 C min. (best performance below 80 F/27 C)
Water temp 90 F/32 C max. 40 F/4 C min. (best performance below 70 F/21 C)
Water pressure 70 P.S.I. max. 10 P.S.I. min.
Plumbing
110CR with 110CT with 110FB with
RIDE ice machine integral ice machine ice machine in base
Dispenser drain 3/4" FPT 3/4" FPT 3/4" FPT
Ice machine drain 3/4" MPT 3/4" MPT 3/4" MPT
Dispenser water inlet 3/8" FPT 3/8" FPT 3/8" FPT
Ice machine water inlet – 3/8" FPT –
RIDE IM water inlet 3/8" OD push-in – –
Cond. inlet – w/c only 3/8" FPT 3/8" FPT 3/8" FPT
Cond. drain – w/c only 3/8" FPT 3/8" FPT 3/8" FPT
Note: Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard piped and insulated, and maintain
slope of at least 1/4" per foot (6mm per 305mm run) of slope. All plumbing connections must be made in accordance with
local building codes.
Ventilation clearances
Countertop models with RIDE ice machine (110CR400A/W) — none. 12" (775mm) at top advised for service.
Countertop models with integral ice machine (110CT400A/W) — 6" (153mm) at top. 6" (153mm) each side advised for
service.
Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top advised for service.