Quick Start Manual

8 110 Series Ice and Water Dispensers
Installation procedures
Installing freestanding dispensers
1. Carefully tip dispenser back to expose underside and block up in place.
2.
Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking care to seat
legs securely against underside of dispenser.
3. Position dispenser in desired location and adjust legs to level in both directions.
4. Connect water supply to 3/8" FPT  tting on back of dispenser (Fig. 1A).
5. Remove 3/4" dispenser drain line plug from back of unit and discard. Connect separate drain lines to 3/4" FPT
dispenser drain  tting and 3/4" MPT ice machine drain  tting on back of dispenser (Fig. 1B and 1C.)
6. Run drain lines to wall or  oor drain. Provide an air break between the drain lines and drain. If ice machine drain  tting
is below an intended wall drain, a condensate pump must be used.
7. If ice machine is water-cooled, connect water-cooled condenser supply line to 3/8" FPT condenser inlet  tting on back
of dispenser (Fig. 1D).
Note: Do not run condenser supply water through ice machine water  lter system.
8. Connect condenser drain line to 3/8" FPT condenser outlet  tting on back of dispenser (Fig. 1E).
Important: Do not connect condenser drain line to any other drain lines.
9. Plug dispenser into 20A rated NEMA 5-20 wall socket.
10. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover to drop
approximately 3/8" (5mm) and pull forward.
11. Turn on water supply and check that water level in  oat reservoir (when full) is within 1/4" (6mm) of mark on side of
reservoir and that  oat moves freely. Check for leaks.
Before you begin
All dispensers must be installed level in both directions to ensure proper operation
Required ventilation and recommended service clearances:
• Countertop models with RIDE ice machine (110CR400A/W) — none. 12" (305mm) at top recommended for service.
• Countertop models with integral ice machine (110CT400A/W) — 6" (153mm) at top. 6"(153mm) each side recommended
for service.
• Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top recommended for service.
All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser. See counter
cutout on page 10 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where utilities will exit
through back of dispenser, refer to back view drawings.
SensorSAFE dispensers are shipped with a plastic, protective  lm on sensor lenses. For proper operation, plastic  lm
must be removed after installation.
Do not tilt unit further than 30° off vertical.
!