Specications
Electrical
 § Freestanding and countertop models (110FB425A/W, 110CT425A/W) require a dedicated circuit.
Total system Max. circuit
Basic electrical: 115 V/60 Hz/1 phase 11.0A 20A
 § Dispensers and ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug. Connect 
to a dedicated 15A circuit.
Model Electrical connection Circuits required
110FB425A/W cord & plug provided 115/60/1, 15A max. fuse size
110CT425A/W cord & plug provided 115/60/1, 15A max. fuse size
Ambient
Air temp* 100 F/38 C Max. 50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp
†
90 F/32 C Max. 45 F/7.2 C Min. (Best performance below 70 F/21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
* 
Ambient air temperature is measured at the air-cooled condenser coil inlet.
† 
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
110CT with integral ice 
machine
110FB with ice machine 
in base
Dispenser drain 3/4" MPT 3/4" MPT
Ice machine drain  3/4 MPT 3/4" MPT
Dispenser water inlet  3/8" FPT 3/8" FPT
Ice machine water inlet 3/8" FPT —
Cond. inlet – w/c only 3/8" FPT 3/8" FPT
Cond. drain – w/c only 3/8" FPT 3/8" FPT
Note:  Water shut-off recommended within 10 ft (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at 
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
 § 110CT425A/W: 6" (15.2 cm) required at top.
Note:  6" (15.2 cm) at each side advised for service.
 § 110FB425A/W: 4" (10.2 cm) required at rear .
Note:  12" (30.5 cm) at top advised for service.
Approximate shipping weight
 § 290 lb (132 kg), base stand: 140 lb (64 kg)