Ice and Water Dispensers 230V 50Hz Operation Manual

Plumbing
Dispenser 3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan
3/8 ID red line tubing for water in
Note: Drains should be hard piped and insulated. Maintain at least 6mm per
304mm run slope on drain line run
Icemaker Refer to Icemaker Installation Manual packed with icemaker for installation instructions
Clearance and access information
1296mm above counter
305mm on side opposite tower, below counter
Counter front or rear panel must be removable for service access to both sides of dispenser and
icemaker(s), if any
Below counter access to drain clean-out required on utility side of dispenser
See Icemaker Installation Manual packed with icemaker(s) for clearance requirements for automatic
load dispensers
4
Side view Front view
553mm
305mm
305mm
696mm
712mm
1264mm
794mm
305mm min
480mm min
153mm min
480mm min
432mm
661mm
water connection
hopper drain
beverage
pan drain
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers