Use and Care

14 Undercounter Dispenser and Ice machine 7UC100A/7UD100A
Service (continued) ––––––––––––––––––––––––––––––––––––––––––––––––––––
10. Unplug the gear motor (three connectors) (Fig.12).
11. Remove ground screw connection.
Fig. 12
12. Remove gear motor:
§ Remove M6 allen screw, retainer, spacer and key (Fig. 13.1).
§ Remove two M6x90 allen screws (Fig. 13.2).
§ Pull gear motor from auger (Fig. 13.3).
§ Remove main housing insulation (Fig. 13.4).
13. Remove all traces of petro-gel from auger shaft.
Fig. 13
2
2
1
3
4
14. Remove compression nozzle:
§ Loosen hose clamp (Fig.14.1).
§ Remove transport tube (Fig. 14.2).
Fig. 14
1