16 Undercounter Dispenser and Ice machine 7UC100A/7UD100A
Service (continued) –––––––––––––––––––––––––––––––––––––––––––––––––––
2 1. Remove and discard mating ring and seal (Fig.18.1).
22. Carefully remove auger (Fig. 18.2).
WARNING!
Use caution when removing auger. The auger is very
sharp - handle with care to avoid personal injury.
Fig. 18
1
2
Evaporator Assembly
1. Remove and inspect main housing O-ring seal. Replace if
damaged in any way.
2. Clean O-ring groove. Lubricate O-ring with Petro-gel and
reinstall.
3. Use cardboard disc to press new mating ring into main
housing (Fig. 19.1).
4. Lube the shaft with liquid soap in the area shown
(Fig.19.2) and slip on seal and spring (Fig. 19.3).
Note: Do not touch the sealing surfaces with bare hands.
Contact with bare skin will cause premature seal failure.
5. Install auger (Fig. 19.4).
Fig. 19
Cardboard
disc
Do NOT
touch!
1
3
4
2
6. Install main housing:
§ Slide main housing onto auger shaft (Fig.20.1).
§ Install three M6x25 allen screws (Fig.20.1).
§ Connect vent line to T tting (Fig.20.1).
Fig. 20
1
2