11. Use screwdriver to orient auger shaft to align with motor
shaft keyway (Fig. 24.1).
12. Install key into keyway (Fig. 24.2).
Fig. 24
1
2
3
13. Install spacer, ensure that key is captured in slot
(Fig.25.1)
Fig. 25
1
14. Insert screwdriver into groove of auger shaft and pry shaft
outwards (Fig.26.1).
15. Insert retainer into groove (Fig.26.2), ensure that retainer
is aligned with hole in spacer.
Fig. 26