Installation Instruction

HARMONY • TOP-MOUNT self-contained
5
Prepare the installation site.
2
H_C1410A/W
NEMA
6-20
H_C1010A/W
NEMA
6-15
H_D710A
NEMA
5-15
1' (0,3 m)
1/4" (6,4 mm)
H_E1010A/W
H_E1410A/W
requires 15A circuit,
1.50 mm
2
wire
requires 20A circuit,
4.00 mm
2
wire
1" Stand pipe/Drain
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
Electrical
• H_C1010/1410(A/W)HT 208-230/60 • H_D710AHT 115/60
H_E1010/1410(A/W)HT 230/50
Requires dedicated 15A circuit.
(H_E1010A/W requires 15A dedicated circuit 1.50 mm
2
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
2
wire)
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
(3/8” push-in internal connection, 3/8” OD tubing required)
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water ltration system (item# 00130286)
This equipment is to be installed with adequate backow protection to comply with applicable
federal, state, and local codes
Condenser water supply for water-cooled systems
(1/4” FPT inlet, 1/4” FPT outlet)
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
(3/4 Barb)
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least
1/4” per foot pitch (6,4mm/0,3m).
Installation site requirements
2.1