Installation Instructions for Remote Condenser

9
REMOTE CONDENSING UNIT
Start up and test
6
Turn dispenser power ON if applicable
Check current draw of compressor to verify correct electrical operation
Put a piece of ice on bin thermostat or hold a cup under the shuttle actuator on the bin/
dispenser to verify that the evaporator unit shuts OFF; condensing unit pumps down and
shuts off.
After shut off, restart the ice machine
Verify operation
6.1
Horizon Condenser Unit Compressor Amperage
Single Phase
Model Number Condensing Unit Running amps (+/- 10%)
1010R
01075365
AJA7490ZXDPN (Tecumseh) 7. 4
1410R
01075373
AWA9513ZXDPN (Tecumseh) 13.7
Three Phase
Model Number Condensing Unit Running amps (+/- 10%)
1010R
01113 12 5
AWA9490ZXTPN (Tecumseh) 6.7
1410R
01113 13 3
AWA9517ZXTPN (Tecumseh) 9.9
1410R
01278373
LZT015M6CFIM (Larkin) 10.7
NOTICE
Ice machine MUST be cleaned and sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for cleaning and sanitizing instructions.