Installation Instructions for Remote Condensing Unit

10
REMOTE CONDENSING UNIT
Start up and test
4
Turn dispenser power ON if applicable
Check current draw of compressor to verify correct electrical operation.
Put a piece of ice on bin thermostat or hold a cup under the shuttle actuator on the bin/
dispenser to verify that the evaporator unit shuts OFF; condensing unit pumps down and shuts
off.
After shut off, restart the ice machine.
Verify operation
4.1
Horizon Condenser Unit Compressor Amperage
Single-Phase
Model Number Condensing Unit Running amps (+/- 10%)
1810R
01146208
MTZ36JG1AVE 19.3
2110R
01146224
MTZ44JG1AVE 20.0
3-Phase
Model Number Condensing Unit Running amps (+/- 10%)
1810R
01146216
MTZ36JG3AVE 10.9
2110R
01146232
MTZ44JG3AVE 14.2
NOTICE
Ice machine MUST be cleaned and sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for cleaning and
sanitizing instructions.