Installation Instructions for Remote Condensing Unit
4
REMOTE CONDENSING UNIT
• Level unit
• Securely attach base of unit using holes
found in base plate
• Required rack system capacity at 0 F
(–18C) evaporator (EPR supplied by
installer).
1810N: 15,700 Btu/hr (3956 kcal/hr)
2110N: 18,200 Btu/hr (4586 kcal/hr)
Condenser installation
2
Install condensing unit
2.1
Condensing unit
1810
Single-Phase
1810
3-Phase
2110
Single-Phase
2110
3-Phase
Electrical 208-230V, 60Hz
Max Circuit HVACR breaker size 45A 25A 45A 30A
Min Circuit Ampacity 26.2A 15.7A 27.1A 19.9A
• Refer to wiring schematic located in condenser unit electrical box
CAUTION
• Electrical disconnects required within
10' (3 m) for all hard wired connections
• Install in accordance with NEC and local
electrical codes
Electrical requirements
2.2