Owners Manual

Specications
Electrical
Each dispenser requires a separate circuit with electrical disconnect within 10 ft (6m). Equipment ground
required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps. For ice machine circuit
requirements, refer to the ice machine specication sheet. Cord and plug provided with each dispenser.
Model Dispenser
number amperage
Single-sided models
VU300M series 6.0 amps
VU300B series 7.0 amps
Dual-sided models
VU300M20D series 8.0 amps
VU300M24D series 8.0 amps
Plumbing
Dispenser 3/4" PVC pipe nipple for bin drain
3/4" PVC pipe nipple for drain pan drain
1/2" ID hose for beverage bath drain
Beverage connections
VU300 single sided units (10 and 12 beverage valves)
Syrup lines - 1/4"
Carbonated and non-carbonated water lines - 3/8"
VU300 dual sided units (12, 20 and 24 beverage valves)
Syrup lines - 3/8"
Carbonated water lines - 1/2"
Non-carbonated water lines - 3/8"
Note: Drains must be hard-piped separately and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett water lter (part# 00130229) on ice machines connected
to automatic ll dispensers.
Ice machine Refer to detailed specications in ice machine installation manual packed with ice machine
5