Owners Manual

Installation
Installing dispenser in counter
Note: All dispensers must be supported from below with supplied 4" – 6" (102 – 153mm) adjustable leg
accessory, or equivalent. Do not hang dispenser on ange.
All dispensers must be installed level in both directions to ensure proper operation.
1. Check that dispenser location meets all requirements in this manual and cut counter as shown.
2. Place support blocks in cabinet to raise dispenser to a height of 12" (305mm).
3. Place dispenser in counter onto support blocks.
4. Attach adjustable legs to dispenser.
5. Remove support blocks and lower dispenser feet to oor.
6. Adjust legs for 1/8" (4mm) clearance between dispenser lip and countertop to verify there is no load on ange.
7. Apply a bead approximately 1/4" (6mm) in diameter of NSF-listed silicone sealant (Dow Corning RTV-732 or
equivalent) around perimeter of dispenser where it meets counter. Smooth sealant to a 1/8" (4mm) radius.
8. Install a PVC drain line with at least a 1/4" per foot (20mm per 1m) slope. Insulate drain line to prevent
condensation.
Note: Do not apply excessive heat if any sweating of ttings is necessary. Heat conduction through metal may
melt threads in plastic drain.
Do not reduce drain line size or tie drains together.
9. Make electrical connections in accordance with applicable wiring diagrams provided. Provide disconnects
within 10 ft (3m) of dispenser and ice machine for servicing.
Min.
33" (839mm)
flat surface
30.375"
(772mm)
38.5" (978mm)
42.5" (1080mm)
11.625"
(296mm)
7. 125"
(181mm)
Dual-sided dispensers cannot be slid into counter
unless raised above counter. Call factory for details.
11.625"
(296mm)
Min.
33" (839mm)
flat surface
30.375"
(772mm)
38.5" (978mm)
48.5" (1232mm)
11.625"
(296mm)
7. 125"
(181mm)
Dual-sided dispensers cannot be slid into counter
unless raised above counter. Call factory for details.
11.625"
(296mm)
Dual-sided 20 valve dispensers – Plan view
Counter cut-out
Min.
33"(839mm)
flat surface
Shaded area is additional cut-out required
f
or slide-in installations only
30.375"
(772mm)
38.5" (978mm)
Single-sided dispensers – Plan view
Counter cut-out
8
Dual-sided 12 & 24 valve dispensers – Plan view
Counter cut-out