User Manual

11
11
indicator light flickering when
control.
flickers when control, then there
is no problem with KBD.
Step 2: If the PTZ indicator light
does not flash when control,
there is some problem with the
RS485 output of the keyboard.
Please return to factory for
repairing.
Video conference camera can
not be controlled by KBD
1.check the control cable
Make sure a right connection of
the control cable.
2.check the correspondence of
camera protocol and baud rate
settings with those of KBD
Check whether the current
protocol and baud rate of each
address are correspondent.
Please refer to camera user
manual.
Not all camera can be controlled
by KBD.
1.Inspect accessories.
Inspect all connection cables.
2.Check settings.
Check whether the current
protocol and baud rate of each
address are correspondent.
3.Probably a problem with star
wiring.
Step 1: At the farthest end of
RS485, connect an impedance
of 120Ω.
Step 2: Add RS485 splitter to the
star connection
Some camera rotate at the same
time when control.
1.Inspect camera address
setting.
Check if the address codes of
the cameras that are moving
together are the same, please
stagger the address code
settings. (Note: you need to
restart after modifying the dialing
switch to take effect)
Forget the locking password
Long press the [SETUP] key to enter the system settings and reset
the password,if happened at any time.
Button silent
Enter the system settings and turn on the button sound.