Parts List

- 34 -
612BJ
7 & 8
DIP 1
1
Not Interlocked
0
Interlocked
7
DIP 2
1
Latching/toggle relay contact
0
Momentary relay contact
DIP4 Set at 1
8
DIP 3
1
Latching/toggle relay contact
DIP4 Set at 1
0
Momentary relay contact
9
DIP 4
1
Latching/toggle relay contact
0
Momentary relay contact
612C-1J/
612C-2J
1 & 2
(2
nd
speed)
DIP 1
1
Both 1
st
and 2
nd
speed contact
relay interlocked when pressed
to 2
nd
speed
Both 1
st
and 2
nd
speed
contact relays activated
0
Both 1
st
and 2
nd
speed contact
relay activated when pressed to
2
nd
speed
Only 2
nd
speed contact
relay activated
9
DIP 2,3
00
Momentary relay contact
DIP 2,3
01
Latching/toggle relay contact
DIP 2,3
10
Activate the 3
rd
speed
10
DIP 4
1
Latching/toggle relay contact
0
Momentary relay contact
612DJ
1 & 2
(2
nd
speed)
DIP 1
1
Both 1
st
and 2
nd
speed contact
relay interlocked when pressed
to 2
nd
speed
Both 1
st
and 2
nd
speed
contact relays activated
0
Both 1
st
and 2
nd
speed contact
relay activated when pressed to
2
nd
speed
Only 2
nd
speed contact
relay activated
---
DIP 2,3,4
0
Momentary relay contact
DIP2&3 Must set to
0 all the time
(In-plant set at 0”)
612E-1J/
612E-2J
1 & 2
(2
nd
speed)
DIP 1
1
Both 1
st
and 2
nd
speed contact
relay interlocked when pressed
to 2
nd
speed
Both 1
st
and 2
nd
speed
contact relays activated
0
Both 1
st
and 2
nd
speed contact
relay activated when pressed to
2
nd
speed
Only 2
nd
speed contact
relay activated
7 & 8
DIP 2
1
Not Interlocked
0
Interlocked
7
DIP 3
1
Latching/toggle relay contact
DIP2 Set at 1
0
Momentary relay contact
612
AJ/BJ/C-1J/
C-2J/DJ/
E-1J/E-2J
11
DIP 7
1
Latching/toggle relay contact