User Manual

Table Of Contents
17
WWW.FORNEYIND.COM
1. Serial number of the unit
2. Welder model
3. Type of characteristic
4. Min. - Max rated No Load Voltage
5. Type of welding
6. Symbol for the main supply and no. of phases
7. Rated value of the supply voltage
8. Code letter for degree of insulation
9. Protection degree
10. Power
11. Size of the necessary main fuse
12. Supply current
13. Welding supply and voltage
14. Power Factor
15. Control range (current / voltage)
16. Reference standard
Attach the ground clamp to the bare metal to be welded, making sure of good contact;
Make sure that the wire-roller groove in the roller corresponds to the diameter of the wire
being used.
Plug the machine into a suitable outlet.
Completely open the gas cylinder valve. Adjust the gas pressure regulator to the correct
flow rate.
Some experience is required to adjust and use a MIG welder. In MIG welding two parameters are
fundamental: the welding voltage and the wire speed. The resulting welding current is a result of these
two settings.
Set the voltage and wire feed controls to positions suitable for the thickness of the material
to be welded. Welding current varies in relationship to wire feed speed. For low welding
current output, the wire feed speed potentiometer should be set at the low end of the wire
feed speed scale. Turning the wire feed speed control potentiometer clockwise will result
in increased wire feed speed and welding current. Welding voltage is adjusted to match
the wire feed speed (welding current). Progressively select higher voltage positions while
increasing wire speed.
Technical Data Information Guide
Welding Preparation
Factors to Consider for Best Welding Results