Installation Guide

STICK TROUBLESHOOTING TIPS
*Performance may vary by brand
Connect to input power
Recommended electrodes
4. 6.
Adjust amperage per
settings chart on the
welder
5.
Connect electrode
holder and ground
clamp according to
desired polarity
3.
Usually
DCEP -
Electrode
Positive
STICK QUICK START GUIDE
220 ST PRO WELDER
ITEM# 430
Read user manual
Select process
2.
1.
Electrode Holder
Ground
Clamp
Electrode
Electrode Amperage
3/32” 1/8” 5/32”
E6010
E6011
E6013
E7014
E7018
E308L
Ni55
30-75 75-125 110-165
40-85
40-90
70-90
65-100
40-70
50-65
75-125
70-110
90-140
110-165
75-115
80-95
110-165
115-140
140-190
150-220
105-160
110-135
Use 3/16” diameter electrodes or smaller. Some 3/16” will draw too
much amperage.
Trying to weld single pass on material larger than 3/8” thick is not
possible with this machine. Multi-pass recommended for thicker
materials.
Welder should be the only thing plugged into the circuit.
Frequently tripping circuit breaker or exceeding
duty cycle
QUESTIONS OR TROUBLE? Contact Forney Industries at 1-800-521-6038 customerservice@forneyind.com
forneyind.com
To ensure maximum quality, always clean
and prepare welding surfaces.
Workpiece Preperation
Connect ground clamp to clean, bare metal. No rust,
paint or other coatings. Attach the ground clamp
directly to the workpiece if you are experiencing issues.
Workpiece grounding
• Usually due to low input power.
• Welder should be only thing plugged into circuit.
• Avoid using extension cords. If one must be used, it must be 3 conductor #12 AWG
or larger up to 25 feet
• Generators must be a minimum 5,000W continuous output with no low-idle function
(or low-idle off), 5% THD Max.
Low weld output or poor fusion
110-120V
Low weld output or poor fusion
• Usually due to low input power.
• Welder should be only thing plugged into circuit.
• Avoid using extension cords. If one must be used, it must be 3 conductor #8 AWG.
• Generators must be a minimum 10,000W continuous output with no low-idle
function (or low-idle off), 5% THD Max.
208-240V
• Generator OK with continuous output >
5,000 W (120V) or 10,000 W (230V).
• Extension cord: #12 AWG (120V) or #8
AWG (230V) or larger. 25’ (8m) or shorter
extension cords recommended