The bottom of the hood should be 30" min. to 36" above the countertop. This would typically result
in the bottom of the hood being 66" to 72" above the floor. These dimensions provide safe and
efficient operation of the hood.
After Installation:
1. Check ignition of cooktop burners.
2. Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.
3. Check ignition of oven burner.
4. Visually check tubular burner (oven burner) re-ignition to be sure both rows of
burner ports are relighting each time.
5. Check for gas leaks at all gas connections (using a gas detector, never a flame).
6. Check oven bake and convection bake function.
Gas Conversion Operation
This cooking range can be used with LP gas and NG gas. It is shipped from the factory adjusted
for use with NG(Nature Gas). Conversion nozzles are included. Follow the instruction shown
below for gas conversion.
Gas conversion shall be conducted by a factory- trained professional.Call the
customer service hotline to identify a factory-trained professional near your home.
Before carrying out this operation, disconnect the range from gas and electricity.
1. Pressure regulator 5. Gas valves
2. Cooktop burners 6. Reconnect Gas and Electrical Supply
3. Oven burner 7. Air shutter oven burner
4. Broil burner 8. Installation of new rating label
Exhaust Hood Installation
18