WARNING Do not obstruct the flow of combustion air into the range and
ventilation air away from the range.
Ventilation: it is recommended that the unit be operated with an oven head, vented exhaust hood of sufficient size and
capacity.
Electric Power Supply Requirements
Pressure Regulator
Pressure regulator can withstand a maximum input pressure of 0.5 psi (3.5 kPa),
and is set at 5" wc out let pressure.
Gas Shut-off Valve (not included)
The supply line must be equipped with an approved external gas shut-off valve located near the range in an
accessible location. Do not block access to the shut-off valve. Refer to the illustration below.
A 3/4" (19) ID gas supply line must be provided to the range. If local codes permit, a certified, 3' (.9 m) long,
1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the unit’s 1/2" NPT
female inlet to the gas supply line. Pipe joint compounds suitable foruse with natural or LP gas should be
Area allows for flush installation with
through-the-wall connection of pipe
stub/shut-off valve and rear wall 120V
outlet.
Shortest connection from hard pipe stub
location to range hook-up.
Area allows for flush installation with through-the-floor
connection of pipe stub/shut-off valve
shut-off valve at open position
Connect to appliance
Gas supply
14
Since service pressure may fluctuate with local demand, every gas cooking range must be equipped with
a pressure regulator on the incoming service line for safe and efficient operation. For GAS RANGE
models : “The pressure regulator shipped with the range has two female threads 1/2" NPT for the 30”
and the 36” or 3/4" NPT for the 48”.
For DUAL FUEL models : ”The pressure regulator shipped with the range has two female threads 1/2"
NPT for the 30”, 36” and the 48”.
The regulator shall be installed properly in order to be accessible when the appliance is installed in its
final position.