The supply line must be equipped with an approved external gas shut-off valve located near the range in an accessible
location. Do not block access to the shut-off valve. Refer to the illustration below.
A 3/4" (19) ID gas supply line must be provided to the range. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or
3/4" (19) ID flexible metal appliance connector is recommended to connect the unit’s 1/2" NPT female inlet to the gas
supply line. Pipe joint compounds suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply piping system during any pressure testing of
the system at test pressures in excess of 0.5 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure testing of the system at test pressures equal to or less
than 0.5 psi (3.5 kPa).
Product Dimensions and Cabinets
This range may be installed directly adjacent to existing countertop-height cabinets (36" or 91 cm from the floor). To achieve
the best look, the cooktop should be level with the cabinet countertop. This can be accomplished by raising the unit using
the adjustment spindles on the legs.
Connect to appliance
Gas supply