Installation Guide

14
Step 3: Make Electrical Connection (continued)
A Ground Screw
B Terminal Block
C Jumper Wire
D Power Cord Wires
E UL Listed Strain Relief
5. Remove the green jumper wire from under the ground screw and replace with the green wire from the power cord
and tighten ground screw.
6. Loop the green jumper wire removed from the ground screw back onto its end that is fastened to the center post on
the terminal block.
7. Use a 5/16” nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10-32 hex
nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer posts of the terminal block
with the corresponding red and black wires from the range.
9. Tighten the hex nuts completely, and then verify the connection.
NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 50-amps that is
marked for use with nominal 1 3/8” (3.5 cm) diameter connection opening, with ring terminals and marked for use
with ranges.
10. Position the lower part of the strain relief under the power cord and tighten the strain relief screws.
NOTE Before tightening, make sure the strain relief is positioned over the cord and NOT the wires.
11. Replace the electrical access panel.
12. Plug range into grounded outlet.
13. Tuck excess power cord into the recessed area of the back panel.
Electrical Shock Hazard
Plug into a grounded outlet.
Do not use an extension cord.

WARNING
1. Plug into a standard 14-50R grounded wall receptacle
2. Go to STEP 4 - INSTALL RANGE 3