Installation Guide
17
A Junction box
B Black Wires
C Red Wire
D Cable from Range
E UL listed or CSA Approved Conduit Connector
F Ground (Green or Bare) Wires
G UL Listed Wire Connectors
H Neutral (White) Wires
I House Electrical Supply
3.
relief nut.
4.
NOTE:Allow enough slack to easily attach the wiring to the terminal block.
Step 3: Make Electrical Connection (continued)
A Jumper Wire
B UL Listed Strain Relief
C Conduit
5.
metal conduit to the center terminal block post along with the green jumper wire from the range.
6. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer posts of the terminal block
with the corresponding red and black wires from the range.
7. Tighten the hex nuts completely, and then verify the connection.
8.
9. Replace the electrical access panel.
10. Tuck excess conduit into the recessed area of the back panel.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL)
Connect To The House Electrical Supply - U.s.a. Only
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding
through neutral, new branch circuit installations (l99e NEC), mobile homes and recreational vehicles, new construction
and in Canada.
Grounded Neutral