Location Requirements (continued)
Electrical Requirements
Power Supply
IMPORTANT: To connect to an outlet in the wall, the electrical outlet must be recessed. If the electrical outlet is on the
”
30”
”
3”
Recommended location
for electrical outlet
IMPORTANT: This appliance is manufactured with the chassis connected to the neutral by a green ground jumper wire.
Use a 3-wire, UL listed, 50-amp power supply cord (pigtail); or if local codes do not permit ground through the neutral,
use a 4-wire power supply cord rated at 250 volts, 50 amps and intended for use with ranges. The ground must be re-
vised so the green ground wire of the 4-wire power supply is connected to the chassis. See “4-Wire Connection: “Power
Supply Cord” and “Direct Wire - U.S.A. Only” “4-Wire Connection (Ungrounded Neutral)” sections.
the ground path is adequate and wire gauge is in accordance with local codes.
To properly install your range, you must determine the type of electrical connection you will be using and follow the in-
structions provided for it here.
•
4-wire, single-phase power supply.
Frequency Amps Circuit Required
50 A 50 Amp Circuit
43 A 45 Amp Circuit
• When a 4-wire, single phase 120/240-volt, 60 Hz., AC only electrical supply is available, a 50-amp maximum circuit
Hz., AC only electrical supply is available, a 45-amp maximum circuit protection is required).
• For direct wire installations, install a suitable conduit box (not furnished). An appropriately sized UL conduit connector
must be used to correctly attach the conduit to the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and grounding must comply with all applicable
local codes.