Installation Guide

9
Electrical Requirements (continued)
ELECTRICAL REQUIREMENTS - U.S.A. ONLY
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical
Code, ANSI/ NFPA No. 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection
Association One Batterymarch Park Quincy, MA 02269.
Electrical Shock Hazard
󰀨
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the green wire (the ground wire) must be connected to a
suitable ground. This wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non metallic gaskets, union connections or other insulating materials, DO
NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or GROUNDING circuit could
result in an electrical shock.


WARNING
Electrical Shock Hazard
Disconnect power before servicing. Plug into a grounded outlet.
Do not use an extension cord.

WARNING

14-50R type SRDT or ST (as required) power cord rated at 250-volt AC minimum, 50 amp, with 3 open-end spade
lug connectors with upturned ends or closed loop connectors and marked for use with ranges.
A UL listed strain relief must be attached to the range to hold the power cord.
• Do not use an aluminum wire receptacle with copper-wired power cord and plug (or vice versa). The proper wiring and
receptacle are a copper-wired power cord with a copper-wired receptacle.
• The electrical outlet should be located so that the power cord is accessible when the range is in the installed position.
ELECTRICAL REQUIREMENTS - CANADA ONLY

the ground path is adequate and wire gauge are in accordance with local codes.