Installation Manual

9
ATTENTION:
There is a stainless steel door and stainless kick plate option. Please consult the authorized service.
Ventilation:
Vent holes where the air enters and exits the unit must not be blocked or obstructed. In addition, you must
periodically clean the dust and dirt that accumulate on these holes in time.
Electrical Connection:
Never use an extension cable.
The power socket must definitely be grounded and checked by an authorized person.
Location of the electrical wiring must comply with the dimensions specified in the manual.
ATTENTION:
RISK OF ELECTRIC SHOCK
Electrical grounding is necessary. This appliance is equipped with a three-pin plug
to protect you against possible electric shocks.
Do not remove the round grounding terminal from the plug.
Do not use two-pin grounding adapters.
Do not use extension cables to energize the product.
ATTENTION:
Do not connect the grounding cable to the gas pipe. Please have the grounding checked by a qualified electrician if
you are not sure about the grounding of the product. Do not install a fuse on the neutral line or grounding circuit.
WARNING:
Please wait for 3-6 hour before energizing the product to protect it against possible damages. This way, the
refrigerant and the lubricants in the system get balanced.
Water Connection
Pressure of the mains water must be in compliance with the values specified in the manual.
Location of the water system must comply with the dimensions specified in the manual.
IMPORTANT INFORMATION:
Bypass is recommended for the water filtering system if a reverse osmosis system is used.