Security System User's Guide

Quick Configuration Guide Powering off the FortiGate-5001A board
FortiGate-5001A Security System Guide
01-30000-83456-20081023 37
To enable fabric backplane data communication from the FortiGate-5001A
CLI
From the FortiGate-5001A board CLI you can use the following steps to enable
fabric backplane data communication.
1 Enter the following command to show the backplane interfaces:
config system global
set show-backplane-intf enable
end
The fabric1 and fabric2 backplane interfaces now appear in all Interface lists. You
can now configure the fabric backplane interfaces and add routes, firewall policies
and other configuration settings using these interfaces.
To enable sending heartbeat packets to the FortiSwitch-5003A
Use the following command to enable sending heartbeat packets from the
FortiGate-5001A fabric interfaces. A FortiSwitch-5003A board receives the
heartbeat packets to verify that the FortiGate-5001A board is still active.
The FortiGate-5001A board sends 10 packets per second from each fabric
interface. The packets are type 255 bridge protocol data unit (BPDU) packets.
1 Enter the following command to enable sending heartbeat packets:
config system global
set fortiswitch-heartbeat enable
end
Powering off the FortiGate-5001A board
To avoid potential hardware problems, always shut down the FortiGate-5001A
operating system properly before removing the FortiGate-5001A board from a
chassis slot or before powering down the chassis.
To power off a FortiGate-5001A board
1 Shut down the FortiGate-5001A operating system:
From the web-based manager, go to System > Status and from the Unit
Operation widget, select Shutdown and then select OK.
From the CLI enter execute shutdown
2 Remove the FortiGate-5001A board from the chassis slot.
Note: Once a shutdown operation is completed, the only way to restart the
FortiGate-5001A board is to remove and reinsert it.