OutBack Integration Guide

Rev1.6_01-22-22
Set Up Fortress Power Lithium Batteries with Outback Systems
505 Keystone Rd, Southampton, PA 18966 . (877) 497 6937. sales@fortresspower.com . Fortresspower.com
3
Charge Controller Settings
Charge Controller
Absorb Voltage and Time
55.2, 2 hours
Float Voltage
54.4
Rebulk Voltage
52.5
DC Current Limit
LFP-10: 80A per battery ÷ # of controllers
eVault: 170A per battery ÷ # of controllers
eFlex: 55A per battery ÷ # of controllers
Absorb End Amps
1A
Communication Settings
FLEXnet DC (FN-DC)
If FLEXNET DC display voltage is not within 0.1V of
inverter terminal voltage, calibrate Outback equipment
Battery Amp hour
eFlex :105Ah per battery
LFP-10: 200Ah per battery
eVault: 360Ah per battery
Charged Voltage
54.0V
Charged Time
15 minutes
Charged Return Amps
1A
Battery Charge
96%
Relay Invert Logic
No *User adjustable
Relay Voltage
High = 53.8 Low = 51.2 *User adjustable
Relay Delay
High = 1, Low = 0 *User adjustable
MATE3/MATE3s
FLEXnet DC Advanced
Low SOC Warning = 20% *User adjustable
FLEXnet DC Advanced
Critical SOC Warning = 10% *User adjustable