Fortress Power Lithium Batteries Using Schneider Insight
Schneider XW Pro and Insight Home Facility or Gateway support operating Fortress Power batteries in closed loop
communication mode. It is best practice to have the inverters programmed in the open loop settings before setting up
closed loop communication. For any additional help, please contact techsupport@fortresspower.com
1. Table of Contents
1. Introduction ........................................................................................................................................................ 2
2. Communication Settings ...................................................................................................................................... 3
Step 1: Hardware Integration .................................................................................................................................. 3
eFlex 5.4kWh ....................................................................................................................................................... 3
eVault Classic 18.5kWh ........................................................................................................................................ 5
eVault Max 18.5kWh ........................................................................................................................................... 6
Step 2: Software Integration .................................................................................................................................... 7
1. Mode Settings.....................................................................................................................................................10
Standard Settings....................................................................................................................................................10
Ac Coupling & Back up Settings ...............................................................................................................................12
Grid-Tied Export .....................................................................................................................................................13
Self-Consumption (Zero Grid Export) .......................................................................................................................14
Off-Grid ..................................................................................................................................................................15
2. Open Loop Settings .............................................................................................................................................16
Settings for Fortress Batteries with Schneider Inverters ...........................................................................................16
Settings with Schneider Charge Controllers .............................................................................................................17
3. Additional Options ..............................................................................................................................................17
Generator Settings (Applicable to all Mode Settings) ...............................................................................................17