Installation Guide

Installation Instructions for Fortress
Pure View Full Glass Railing Panels with
13
Evolve External Brackets and Al Posts
Required Materials
Miter saw with fine-tooth blade, Drill, 3/16” Drill Bits, T-25 Driver Bit, Phillips Head Screw Driver, Drill Bit
Extender, Tape Measure, Wrenches, Speed Square, Center Punch, 3-1/2” Support, and Hammer.
Note
When cutting Fortress railing, it is very important to complete the following at cut points.
• Remove all metal shavings from the cut area
• File any sharp edges left by cutting. Thoroughly wipe and remove any filings, grime or dirt from the railing.
Apply two coats of Fortress zinc based touch-up paint to the cut area. If touch up is at rail ends, allow paint to dry before
connecting bracket to post.
• Be sure to remove any metal shavings from the surface of deck, patio or balcony to prevent corrosion on the surface.
It is the responsibility of the installer to meet all code and safety requirements, and to obtain all required building permits.
The deck and railing installer should determine and implement appropriate installation techniques for each installation
situation . The Fortress Company or its distributors shall not be held liable for improper or unsafe installations.
13 13
Fortress Al Posts must always be secured to the deck framing. Fortress Al Posts should never be attached to only the
deck boards.
For technical assistance, please email: technicalhelp@fortressrailing.com
Hours of Operation Monday through Friday 8:00 AM to 5:00 PM, CST
Phone: 1-866-323-4766 Fax: 972-644-3720
www.fortressrailing.com
Torx Safety Tips
Always pre-drill holes with a 3/16” drill bit.
Always use the lowest speed setting on drill.
• To reduce chance of bit breakage, start tightening with drill on low torque setting and work up until screw is secured.
1/2” minimum
Added Blocking
Deck Framing
Deck Framing
Deck Framing
Base Plate Barrier
must be placed
between Post Base
and Deck Surface
13
Mount Al Posts*
• Wood Blocking tied to deck frame must be installed and constructed with treated dimensional lumber with a minimum
thickness of 1-1/2”.
Al
13
3” Post Spacing must not exceed 72” for 6’ Panels.
Position the edge of post base plate a minimum of ½” from the inside edge of rim joist.
Place included Base Plate Barrier between post base and deck surface.
• Mount posts at appropriate points based on panel length.
Attach Al
13
posts with 3/8” X 3-1/2” Hex Head galvanized bolts.
13
*Reference Fortress Al Post mounting instructions
REV 050215
1/4