User's Manual

ES210 Hardware Guide: LEDs and Pushbutton Operation
16
NOTE: You can
also change the
Blackout Mode setting in
the Mesh Point GUI (see
the
Software GUI Guide)
or in the Mesh Point CLI
(see the
Software CLI
Guide).
If Blackout Mode is Disabled, the actions below will enable it. If
the setting is
Enabled, the same steps will disable it.
1 Press the lower button on the left side of the chassis.
2 Hold it down for five seconds.
3 Release the button.
The new setting persists over reboots and upgrades, just as
when changed through the Mesh Point GUI or CLI.
3.2.3 Pushbutton RF Kill Operation
NOTE: You can
also change the
RF
Kill
setting in the Mesh
Point GUI (see the
Soft-
ware GUI Guide).
The upper button on the left side of the chassis toggles the
Mesh Point’s
RF Kill function.
The default
RF Kill setting is Disabled, in which state the Mesh
Point receives and transmits radio frequency signals normally.
Enabling
RF Kill turns the Mesh Point’s internal radio off. When
RF Kill is enabled, the top-panel Radio LED lights solid green to
indicate that radio operation has been suspended.
If
RF Kill is Disabled, the actions below will enable it. If the
setting is
Enabled, the same steps will disable it.
1 Press the upper button on the left side of the chassis.
2 Hold it down for five seconds.
3 Release the button.
The new setting persists over reboots and upgrades, just as
when changed through the Mesh Point GUI or CLI.
3.2.4 Pushbutton Restoring Defaults
To restore the Mesh Point’s configuration settings to their
factory-default values:
NOTE: You can
also restore the
Mesh Point’s factory de-
fault settings from the
Mesh Point GUI (see the
Software GUI Guide) and
the Mesh Point CLI (see
the Software CLI Guide).
1 Simultaneously press the upper and lower buttons on the
left side of the Mesh Point chassis.
2 Hold them down for at least ten seconds.
3 Release both buttons.
After you have successfully initiated the restore operation, the
Mesh Point will reboot automatically.
After booting, the Mesh Point LEDs will resume normal
operation and all configuration settings, including the IP
address of the Mesh Point’s management interface will be at
their factory-default values.