User's Manual

ES2440 Hardware Guide: Installation
7
internal radios, as shown below, and one for the ES2440
internal GPS.
Figure 2.2. ES2440 Back-Panel Antenna Connectors
The grounding stud is the wing nut located on the left rear
corner of the chassis, viewing the ES2440 from the front
(refer to Figure 2.1),
2.2 Connecting the ES2440
The ES2440 can be connected temporarily to preconfigure the
Mesh Point software, and then permanently for deployment.
2.2.1 Connections for Preconfiguration
Mesh Point software should be configured in advance of
deployment. This section provides instructions for temporarily
connecting the ES2440 Mesh Point for preconfiguration.
1 Position the Mesh Point so that it operates only within its
safe temperature range.
2 Connect the Mesh Point to a power source, either through
the
Ethernet1/WAN/POE port using the included PoE+
adapter/injector or through the
DC Power inlet to external
10–30 VDC power. Refer to Section 2.1.2, Powering
Options, for additional detail.
3 Connect an Ethernet cable to one of the ES2440’s default
clear Ethernet ports:
Ethernet2 or Ethernet3, and connect
the other end to a computer or a switch on the wired LAN.
To complete the configuration, refer to the Software GUI Guide
or the Software CLI Guide for instructions on Logging On,
Licensing, and Configuring the Mesh Point software.
antenna port 1 Radio 2
antenna port 1 Radio 3
antenna port 1 Radio 4
antenna port 1 Radio 1
antenna port 2 Radio 2
antenna port 2 Radio 3
antenna port 2 Radio 4
antenna port 2 Radio 1
GPS antenna port
QA review draft1