To run FIPS tests manually:
1 Log on to the Bridge GUI through an Administrator-level
account and select
ADVANCED VIEW in the upper right corner
of the page, then
Maintain -> System from the menu on the
left.
2 In the System screen’s FIPS Retest frame, click EXECUTE.
6.1.8 Restoring Default Settings
NOTE:
Licensed
features are re-
tained even after the
Bridge
is reset to factory
defaults.
With the exceptions of any special features it has been
licensed to use, the Fortress Bridge’s factory default
configuration settings can be restored in their entirety.
Because the Bridge’s configuration settings could themselves
be sensitive, Fortress Technologies recommends restoring
them to their default values whenever the Bridge is to be
shipped (or otherwise transported) out of a secured location.
In order to fully restore the Bridge to its factory configuration
defaults, you must perform a separate restore operation for the
software image on each of the Bridge’s flash memory partitions
(refer to Section 6.1.4).
You can reset to factory defaults only in Advanced View.
Figure 6.8. Advanced View
Reset to Factory Defaults
frame, all platforms
To restore the factory default configuration:
NOTE: You can
also restore the
Bridge to its factory de-
fault settings with the
chassis controls (refer to
the appropriate Hard-
ware Guide) and from
the CLI (refer to the CLI
Software Guide).
1 Log on to the Bridge GUI through an Administrator-level and
select
ADVANCED VIEW in the upper right corner of the page,
then
Maintain -> System from the menu on the left.
2 In the System screen’s Reset to Factory Defaults frame click
EXECUTE.
3 Click OK at the confirmation query.
At the top of the screen the GUI displays:
Reset to Factory
Defaults - please be patient.
4 Close your browser.