Install Instructions
Typical lineset* capacity LD-92 3
1
/2
”
W x 2
1
/2
”
D LD-122 4
1
/2
”
W x 3
1
/4
”
D
LD-92 w/Single 1
1
/8” Lineset
BTU - 60,000
Suction Line - 1
1
/8”OD
(Insulation) - 1/2”
Liquid Line - 1/2”OD
Drain Line- 3/4”PVC
LD-122 w/Dual 3/4” Lineset
BTU - 36,000
Suction Lines - 3/4”OD
(Insulation) - 1/2”
Liquid Lines - 3/8”OD
Drain Line- 3/4”PVC
LD-92 w/Dual 3/4” Lineset
BTU - 36,000
Suction Lines - 3/4”OD
(Insulation) - 3/8”
Liquid Lines - 3/8”OD
Drain Line- 3/4”PVC
LD-92 w/Single 3/4” Lineset
BTU - 42,000
Suction Line - 3/4”OD
(Insulation ) - 1/2”
Liquid Line - 3/8”OD
(Insulation ) - 1/2”
Drain Hose - 7/8” OD
LD-122 w/Single 1
1
/8” Lineset
BTU - 60,000
Suction Line - 1
1
/8” OD
(Insulation) - 1”
Liquid Line - 1/2”OD
Drain Line- 3/4”PVC
LD-122 w/Dual 3/4” Lineset
BTU - 42,000
Suction Lines - 3/4”OD
(Insulation ) - 1/2”
Liquid Lines - 3/8”OD
(Insulation ) - 1/2”
Drain Hose - 7/8” OD
(1) Determine the path which the line-
set will follow and strike a chalk line to
mark the surface material. Attach the
base only of all ttings rst (ducting
will be placed last), along the marked
path, using fasteners of sufcient
length (not provided). Predrill where
necessary. Duct must terminate
with a tting to prevent cover
from sliding out of position.
Installation instructions
(2) Once all tting bases are se-
cured to the siding, measure and
cut LD Ducting to t as needed.
Remember to account for some
seasonal expansion and contrac-
tion. Install and fasten LD Ducting
bases. Attach bases only to struc-
ture through provided punch outs
using fasteners of sufcient length
(not provided).
(4) Run lineset, drainhose,
wiring etc. over the tting
and duct bases and secure
to duct clips using tie wraps
of sufcient size.
(3) Position and twist in
lineset duct clips (Model#
LDC) evenly spaced through-
out installation. Nylon cable
ties (not included) slip through
lineset duct clips and fasten
around lineset.
(5) Snap straight duct top over
mating straight base pieces. Seat
tting tops over mating tting bases
and secure with provided stainless
screws. Duct must terminate with a
tting to prevent cover from sliding
out of position. If duct is to be
painted, or duct is a dark
color, adhere cover to base
with pvc cement.
ZLI080
* Lineset size may change on Seer Rating
Contact: Airtec Products Corp.
508-675-2669 508-673-0115 www.airtecproducts.com
P F W
Airtec
Airtec