FOS CYCLONE PRO LED Strobe Wash Outdoor Moving Light This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in a safe place for future reference.
TABLE OF CONTENTS 1. Dimension.................................................................................................................. 3 2. Safety Information................................................................................................... 3 3. Preparing for installation......................................................................................... 5 4. Installation..........................................................................................................
1. Dimension 2. Safety Informations WARNING! Read the safety precautions in this section before unpacking, installing, powering or operating this product. This luminaries are multi-environmental fixtures with an IP-rating of 65, intended for professional use only. They are not suitable for household use. Review the following safety precautions carefully before installing or operating the fixture.
WARNING! Risk of electric shock. Always power off/unplug the fixture before removing any covers. Ensure that the power is turned off when connecting the fixture to the AC mains supply. Ensure that the fixture is electrically connected to earth (ground). Do not apply power if the fixture is in any way damaged. Do not immerse the fixture in water or liquid. Preventing burns and fire WARNING! Take measures to prevent burns and fire.
Do not look directly at the light source from close range. Take precautions to prevent injury due to falls when working at height. For permanent installation, ensure that the fixture is securely fastened to a load-bearing surface with suitable corrosion-resistant hardware. For temporary installation with clamps, ensure that the quarter-turn fasteners are turned fully and secured with a suitable safety cable.
normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling. Two quarter-turn brackets are supplied with the fixture if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps.
After connecting the fixture to power, run the on-board test, using the “Fixture Text” menu, to ensure that the fixture and each LED are functioning correctly. See “Control menu” on page 13. CAUTION: Do not open the fixture to replace the supplied power cable, or connect the fixture to an electrical dimmer system, as this can damage it. 6. Configuring the fixture Set up the fixture using the control panel and LCD display at the arm side of the fixture.
Using stand-alone operation Stand-alone operation is where the fixture is not connected to a control device, but is preprogrammed with 2 modes (Auto Color, Auto Fade), that play continuously in a loop, the run speed of “Auto Color”, “Auto Fade” are adjustable. To define a stand-alone program, use the “Auto Program” menus (see “Control menu” on page 13). 7. Connecting to a DMX control device The fixture is controllable using a DMX control device and it can be connected using a DMX cable.
8. Configuring the fixture for DMX control About DMX The fixture can be controlled using signals sent by a DMX controller on a number of channels (which varies depending on the DMX mode that has been set). The first channel used to receive data from a DMX control device is known as the DMX start address. Each fixture must have a DMX start address set. For example, if a fixture has a DMX address of 10 and it is in 4-channel DMX mode, then it uses channels 10, 11,12 and 13.
9. Cleaning To maintain optimal performance, regular cleaning is essential. Cleaning schedules will vary depending on the operating environment, and the installation should therefore be checked at frequent intervals within the first few weeks of operation to see whether cleaning is necessary. This procedure will allow you to assess cleaning requirements in your par- ticular situation. Clean the fixture using a soft cloth dampened with a solution of water and a mild detergent.
86-128 Strobe Mode 3 129-171 Strobe Mode 4 172-214 Strobe Mode 5 215-255 Strobe Mode 6 4 Plate Red 0-255 Plate Red Dimmer 5 Plate Green 0-255 Plate Green Dimmer 6 Plate Blue 0-255 Plate Blue Dimmer 7 Plate Strobe 0-9 No Strobe 10-255 Strobe from slow to fast 14 Channel mode Channel Name DMX Value Description 1 Tilt 0-255 Tilt Movement 2 Tilt Fine 0-255 Tilt Fine Movement 3 Beam Dimmer 0-255 Tube Strobe Intensity 0-5 No Strobe 6-42 Strobe Mode 1 43-85 Strobe Mod
142-183 Tube Macro 4 184-225 Tube Macro 5 226-255 Tube Macro 6 7 Plate Red 0-255 Plate Red Dimmer 8 Plate Green 0-255 Plate Green Dimmer 9 Plate Blue 0-255 Plate Blue Dimmer 10 Plate Strobe 0-9 No Strobe 10-255 Strobe from slow to fast 0-4 Plate Macro Off 5-9 Plate Macro 1 10-14 Plate Macro 2 15-19 Plate Macro 3 … Plate Macro … 250-254 Plate Macro 50 255 Plate Macro 51 11 Plate Macro 12 Plate Macro Color 0-255 Plate Macro Color 13 Plate Macro Speed 0-255 Speed
5 6 Beam Duration Beam Macro 215-255 Strobe Mode 6 0-255 Tube Flash Duration 0~3s 0-15 Tube Macro Off 16-57 Tube Macro 1 58-99 Tube Macro 2 100-141 Tube Macro 3 142-183 Tube Macro 4 184-225 Tube Macro 5 226-255 Tube Macro 6 7 Plate Red 0-255 Plate Red Dimmer 8 Plate Green 0-255 Plate Green Dimmer 9 Plate Blue 0-255 Plate Blue Dimmer 10 Plate Strobe 0-255 Plate Strobe 0-4 Plate Macro Off 5-9 Plate Macro 1 10-14 Plate Macro 2 15-19 Plate Macro 3 … Plate Macro …
41 Plate Pixel 8 Green 0-255 Plate Pixel 8 Green Dimmer 42 Plate Pixel 8 Blue 0-255 Plate Pixel 8 Blue Dimmer 11. Control menu Display: MENU DOWN UP ENTER To select the programming functions (press to unlock screen) To go backward in the selected functions To go forward in the selected functions To confirm the selected functions Set DMX Address: 1. Press "MENU" to unlock screen, then select the “DMX Address” and press "ENTER". 2.
Mode 42 Channel Mode 42 channels DMX mode Dimmer Mode 1 Dimmer Mode Dimmer Mode 2 Dimmer Mode 3 Dimmer Mode 4 Dimmer Mode 5 Dimmer Curve 1 Dimmer Curve Dimmer Curve 2 Dimmer Curve 3 Dimmer Curve 4 Manual Color Tilt 000~255 Tilt Fine 000~255 Aura Dimmer 000~255 Aura Strobe 000~255 Aura Red 000~255 Aura Green 000~255 Aura Blue 000~255 Aura Macro 000~255 Aura Macro Color 000~255 Aura Macro Speed 000~255 White Dimmer 000~255 White Strobe 000~255 White Macro 000~255 White Macro
Factory Settings System Info NO YES RDM UID RDM UID Version Software Version Number DMX Channel Currently used mode Run Time 00:00:00 Total usage time User Time 00:00 The time of use Temperature Current Operating Temperature 12. Specification Strobe Panel LEDs LED Type: 5050 0.
Cooling: Temperature controlled, overheating protection Effects Dimmer: 0-100% electronic Shutter: electronic, max.
Weight N.W: 10 kg G.W: 12.