Installation Manual

© 2015 Sensata Technologies
Page 47
Troubleshooting
Figure 6-1, Performing an Inverter Reset
6.1.2 Performing a Power Reset (i.e., hard reset)
To perform a power reset (also known as a “hard reset”):
1. Open the inverter’s positive DC disconnect (or disconnect the positive battery cable to the
inverter).
Note: If parallel stacked with multiple inverters, open all the inverters’ DC disconnects at the
same time.
CAUTION: If removing all battery power (positive and negative) to the inverter, do
not remove the DC negative connections to the inverter or any accessory until after
all positive battery connections have been disconnected. This will prevent damage to
the inverter or to any network connected accessory.
2. Ensure the inverter and the remote are disconnected from all AC and DC power (the remote
display will be blank).
3. After the inverter has been disconnected from all power for 30 seconds, reconnect the inverter
DC disconnects (or reconnect the positive battery cable) and resume operation.
Info: If DC disconnects are not used, there may be a momentary spark when the positive
battery cable is connected to the inverter’s terminal. This is normal and indicates that
the inverter’s internal capacitors are being charged.
6.1 Resetting the Inverter
Under some fault conditions (e.g., an internal fault), the inverter will need to be reset.
WARNING: A soft reset should not be performed with parallel stacked inverters. If a
reset is required, perform a hard reset instead (see Section 6.1.2).
Prior to performing any reset, ensure all AC power (utility, generator, shorepower) is removed
from the inverter’s input.
CAUTION: If AC is connected while performing an inverter reset, damage may occur.
6.1.1 Performing an Inverter Reset (i.e., soft reset)
To perform an inverter reset (also known as a “soft reset”):
1. Press and hold the Power ON/OFF pushbutton (see Figure 6-1) for approximately ten (10)
seconds until the Charging/Inverting Status LED comes on and ashes rapidly.
2. Once the rapid ashing has begun, release the Power ON/OFF pushbutton. The Status LED will
go off after the pushbutton is released.
3. After the inverter reset is completed, press the ON/OFF pushbutton to turn the inverter ON.
If the inverter reset fails, you will need to perform a power reset using the procedure below in
Section 6.1.2. In either case, if an internal fault does not clear, the inverter will require repair at
an Authorized Service Center (ASC).
Info: The Power ON/OFF pushbutton is a small momentary type switch which operates
by lightly pressing and releasing. Be careful not to apply too much force when pushing
or the switch might break.
2. Watch the Charging/Inverting Status LED,
after approximately 10 seconds it should come
on and ash rapidly (i.e., utter) to indicate
the inverter has reset. The Status LED will go
off after the pushbutton is released.
1. Press and hold the Power ON/
OFF pushbutton.