MS-PAE 120/240V SERIES SPECIFICATIONS
MS4024PAE MS4448PAE
INVERTER SPECIFICATIONS
Input battery voltage range 18 - 34 VDC 36 - 64 VDC
Nominal AC output voltage 120/240 VAC split phase (± 5%) 120/240 VAC split phase (± 5%)
Output frequency and accuracy 60 Hz ± 0.1 Hz 60 Hz ± 0.1 Hz
Total Harmonic Distortion (THD) < 5% < 5%
1 msec surge current (amps AC) Line-Neutral: 120, Line-Line: 70 Line-Neutral: 120, Line-Line: 70
100 msec surge current (amps AC) Line-Neutral: 72, Line-Line: 40 Line-Neutral: 75, Line-Line: 40
5 sec surge power (real watts) 5800 8500
30 sec surge power (real watts) 5200 6000
5 min surge power (real watts) 4800 5400
30 min surge power (real watts) 4500 4800
Continuous power output at 25° C 4000 VA (L-L) 4400 VA (L-L)
Maximum continuous input current 266 A 144 ADC
Inverter efficiency (peak) 93% 94%
Transfer time 16 msecs 16 msecs
Search mode (typical) < 6 watts < 6 watts
No load (120 VAC output, typical) 27 watts 25 watts
Waveform Pure Sine Wave Pure Sine Wave
CHARGER SPECIFICATIONS
Continuous output at 25° C 105 ADC 60 ADC
Charger efficiency 85% 85%
Power factor > .95 > .95
Input current at rated output (AC amps)
15 AAC per leg
at 120/240 VAC split phase
17.5 AAC per leg
at 120/240 VAC split phase
GENERAL FEATURES AND CAPABILITIES
Transfer relay capability 2 legs at 30A per leg transfer standard on all models
Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Battery temperature compensation Yes, 15 ft Battery Temp Sensor standard
Internal cooling 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans
Overcurrent protection Yes, with two overlapping circuits
Overtemperature protection Yes on transformer, MOSFETS, and battery
Corrosion protection Yes, PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners
Listings ETL Listed to ANSI / UL1741, 1
st
edition, and CSA STD C22.2 No.107.1-01
Warranty Three years parts and labor (five years when installed on MMP or MP system)
ENVIRONMENTAL SPECIFICATIONS
Temperature (Operating/Non-operating) -20° C to +60° C (-4° F to 140° F) to -40° C to +70° C (-40° F to 158° F)
Operating humidity 0 to 95% RH non-condensing
PHYSICAL SPECIFICATIONS
Dimensions (l x w x h) 13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)
Mounting Shelf, wall (no vents on bottom), MP or MMP panels
Weight 55 lb (24.9 kg) 55 lb (24.9 kg)
Shipping weight 62 lb (28.2 kg) 63 lb (29.6 kg)
Max operating altitude 15,000’ (4570 m)
Testing for specifications at 25° C. Specifications subject
to change without notice.
February 2017 Rev D Part #64-0275