Specifications

COMPANY CONFIDENTIAL
30
4. Electrical Specifications
4.1 Recommended operating conditions
Table 4-1 Recommended operating conditions
Parameter Min Type Max Units
Storage temperature -30 +25 +85 °C
Recommend operating temperature
(3GPP compliant) (*1)
-30 +25 +70 °C
Extendable (with limited performance)
Temperature measure on T77W968 module(*2)
-40 +85
Operating voltage 3.135 3.3 4.4 Vdc
Note: The operating temperature reference point is board temperature on module bottom side (Ground Golding
plating area)
(1)Refer application note about thermal mitigation plan
(2).Extendable operation allows normal mode data transmission for limited time until
automatic thermal shutdown takes effect. Within the extendable temperature range (outside
the operating temperature range) the specified electrical characteristics may be degraded.
(3).Due to temperature measurement uncertainly, a tolerance on the stated shutdown
thresholds may occur. The possible deviation is in the range of +/- 2 at the
over-temperature and under-temperature limit.
(4). Need implement thermal solution on Platform (Example add thermal pad to heat
dissipated from LTE module to Platform PCB) would get more thermal margin and benefit
then extend the operating temperature
Operating T77W968 device under conditions beyond its absolute maximum ratings (Table
4-1) may damage the device. Absolute maximum ratings are limiting values to be considered
individually when all other parameters are within their specified operating ranges. Functional
operation and specification compliance under any absolute maximum condition, or after
exposure to any of these conditions, is not guaranteed or implied. Exposure may affect
device reliability
T77W968C9
T77W968C9