Module for siren
Module MOD-SEL
MOD-SEL
Caratteristiche principali
• 2 relay output linked to battery status and tamper of the
connected devices
• Radio coverage up to 200 mt in free space
• Test mode to check radio coverage
• Managing of acquired devices battery by dedicated output
in case of low battery
The module MOD-SEL allows to add up to 2 wireless sirens (WL04SEL) to a wired
control panel, by using a bi-directional radio connection.
The Led and buzzer integrated provide information about the data transmission
and reception, siren set-up and intensity of the signal.
2 relay connections inform about battery status and tamper of acquired devices.
Item MOD-SEL
code 910341
Power supply and consumption
Power supply voltage V 6-15
Operating frequency MHz 868
Current consumption Stand-by mA 25
max 60
Characteristics
Radio coverage (free space) m 200
Dimensions (lxpxh) mm 120x75x29
Operating temperature °C -40 to +70
Weight g83