Operation Manual

min 50
min 200
h1 = 7
h2 = 40
h3 = 100-109
225
453
453
466
330
225
Installation and technical data
Page 18
Top viewSide viewFront view
Refrigeration unit dimensions (as an example)
Milk container 5 liters
Capacity up to 80 cups
(depending on size)
Electrical connection 220 - 240 V1L N PE160 - 170 W50/60 Hz Fuse: 10 A
Electric cable 1800 mm
Ambient conditions Humidity: max. 80%
Ambient temperature: 5 - 32 °C
Weight approx. 40 kg
Width 334 mm
Depth 471 mm
Height
1
540 mm
Chill & Cup technical data
1
Height without adjustable feet.
40 mm foot (h2) 330 mm + 40 mm = 370 mm
100 mm foot (h3) 330 mm + 100 - 109 mm = 430 - 439 mm
Adjustable feet (optional)
Capacity up to 180 cups (depending on size)
Electrical connection 200 - 240 V1L N PE170 W50/60 HzFuse: 10 A
Electric cable 1800 mm
Weight approx. 10 kg
Width 320 mm
Depth 490 mm
Height
1
540 mm
Milk container 5 liters
Electrical connection
220 - 240 V1L N PE88 W50/60 HzFuse: 10 A
Electric cable 1800 mm
Ambient conditions Humidity: max. 80%
Ambient temperature: 5 - 32 °C
Weight approx. 13 kg
Width 225 mm
Depth 453 mm
Height
1
330 mm
Cup warmer technical data
Technical data for the refrigeration unit
Place the add-on units in line with the Pura and at eye level.
Distance to the wall must be at least 50 mm. Clearance above the ma-
chine must be at least 200 mm.
Adjustable feet (optional) can be used to compensate for unevenness or
height differences.
If optional add-on units are installed, up to an additional 355 mm may be
required per add-on unit.
Add-on unit installation dimensions