Installation Owner manual

2 Page 2 - 2 TANK SENTINEL
®
INSTALLATION GUIDE
TABLE 2-1. STANDARD (STD) TANK SENTINEL PROBES
dimensions are listed in inches (mm)
Probe Probe Maximum Model TSP-LL2
Model Shaft Tank Probe
Length Diameter Overall Length
LL2-29 29(737) 24(610) 39(991)
LL2-41 41(1041) 36(914) 51(1295)
LL2-53 53(1346) 48(1219) 63(1600)
LL2-69 69(1753) 64(1626) 79(2007)
LL2-77 77(1956) 72(1829) 87(2210)
LL2-81 81(2057) 76(1930) 91(2311)
LL2-89 89(2261) 84(2134) 99(2515)
LL2-101 101(2565) 96(2438) 111(2819)
LL2-113 113(2870) 108(2743) 123(3124)
LL2-125 125(3175) 120(3048) 135(3429)
LL2-131 131(3327) 126(3200) 141(3581)
LL2-137 137(3480) 132(3353) 147(3734)
LL2-149 149(3785) 144(3658) 159(4039)
Riser Pipe Length Calculations
Minimum Riser Length
Start with the overall length of the probe, add 5 inches (127mm) for the support
chain, and subtract the tank diameter. See Example minimum riser length
calculations (below) for a TSP-LL2-101 probe in two different sized tanks.
92 Inch (2337mm)Tank 96 Inch(2438mm) Tank
inches (mm) inches (mm)
TSP-LL2-101 Probe Overall Length 111(2819) 111(2819)
Allowance for suspension chain + 5(127) + 5(127)
Total 116(2946) 116(2946)
Tank diameter 92(2337) 96(2438)
Minimum Riser Length = 24(609) 20(508)
It is possible through the minimum riser length equation for the calculation to be
less than 18 inches. It is recommended that the riser be at least 18 inches (457
mm) for a model TSP-LL2 Probe (Reference Figure 2-1).
NOTE